For an outdoor access point (AP), form drip loops at the AP and building entry. Put a grounded surge protector at the entry. Ruckus outdoor AP guidance.
Shape the drip loops
For the AP4060 and AP4060X, form the loop below the AP after weatherproofing the connections. The loop channels water down and away from the connection points. Extreme Networks drip-loop instructions.
- At the AP. Form the loop immediately at the Ethernet connection. Follow any loop size the AP maker specifies. Extreme Networks specifies at least 3 inches for LAN cables entering or exiting a gland on the AP4060 and AP4060X. Extreme Networks drip-loop instructions, Ruckus outdoor AP guidance.
- At the building. Form a second loop at the building entrance. Ruckus outdoor AP guidance.
Place the PoE surge protector
For a cable entering a building, Ruckus recommends a surge protector at the entry to protect indoor equipment. Ruckus outdoor AP guidance.
Ruckus also recommends an outdoor protector for the AP if the AP lacks built-in surge protection. These measures reduce risk from indirect lightning strikes. A direct strike can still damage the installation. Ruckus outdoor AP guidance.
Check PoE and link speed separately. Compare the AP’s power requirements and the planned link rate with the protector’s specifications. For example, Ubiquiti’s ETH-SP-G2 guide lists IEEE 802.3af and 10/100/1000 Ethernet. Ubiquiti ETH-SP-G2 guide.
Ground the AP and surge protector
Have an electrician identify and verify the grounding points. Ruckus recommends a common ground for the outdoor AP, surge protector and indoor network equipment. Ruckus outdoor AP guidance.
- AP chassis. Use the AP’s grounding point. Ruckus outdoor AP guidance.
- Surge protector. For the ETH-SP-G2, Ubiquiti specifies either direct attachment to an already grounded metal pole or structure using the supplied self-tapping screw and shielded twisted-pair cable, or a drain wire to a remote grounding block or structure. For wall mounting with a drain wire, follow Ubiquiti’s wire limits (≤ 16 AWG, ≤ 40 cm). Attach the wire with an M5 machine screw and nut, with the supplied serrated washer between the screw and wire. Ubiquiti ETH-SP-G2 guide.
Evidence and limits. The checklist was drawn from Extreme Networks’ AP4060/AP4060X guide Rev AD, Ruckus support article 000006011 and Ubiquiti’s ETH-SP-G2 Quick Start Guide. No hardware installation was tested.